Call Us at 1-877-887-2232
5 05, 2017

Oil & Gas Remote Monitoring / SCADA Overview

2019-04-30T11:40:20-06:00May 5th, 2017|Categories: Alarm Callout, Communications, Devices, Digital Oilfield, Industrial Internet of Things, Instrumentation, Internet of Things, Monitoring Applications, Oil And Gas Monitoring, Process Control, Programming, Remote Monitoring, SCADA, Security|Comments Off on Oil & Gas Remote Monitoring / SCADA Overview

SCADACore's Oil & Gas SCADA / Remote Monitoring Infographic provides an overview of our complete, one-stop Industrial-Internet-of-Things solution for Oil and Gas Remote Monitoring, Artificial Lift Monitoring, Offset Frac Monitoring, Regulatory Flow Monitoring, Tank Level Monitoring, Surface Casing Vent Pressure Test Monitoring, and Well Test Monitoring. View Full-Size JPG View Full-Size PDF [...]

23 04, 2017

Cloud-Based SCADA

2019-04-30T11:40:22-06:00April 23rd, 2017|Categories: Alarm Callout, Communications, Devices, Digital Oilfield, Environmental Monitoring, Health And Safety Monitoring, Industrial Hygiene Monitoring, Industrial Internet of Things, Industrial Process Monitoring, Instrumentation, Internet of Things, Oil And Gas Monitoring, Process Control, Programming, Remote Monitoring, Remote Surviellance, Renewable Energy, SCADA, Security|Comments Off on Cloud-Based SCADA

Features Cloud-Based SCADA for Industrial Applications SCADACore Live is a Cloud-Based SCADA / Remote Monitoring solution that provides low-cost, fully-featured remote monitoring / hosted web SCADA solutions with 24/7 support. With our innovative technologies and efficient operations, our clients get more, and pay less. Our Cloud-Based SCADA monthly fees are based on devices [...]

15 11, 2016

Alarm Callout Systems

2019-04-30T11:40:26-06:00November 15th, 2016|Categories: Alarm Callout, Environmental Monitoring, Health And Safety Monitoring, Industrial Hygiene Monitoring, Industrial Process Monitoring, Oil And Gas Monitoring, Remote Monitoring, Remote Surviellance, Renewable Energy|0 Comments

Alarm callout systems are imperative for industrial operations. An alarm callout system typically involves a server or device that polls and monitors a sensor or a system for certain conditions or thresholds. When the server or device detects an anomaly, a Voice, SMS, and/or Email report is sent to a user that signal a problem [...]

22 03, 2016

SCADACore announces new Online Heat Stress Alarm Station

2019-04-30T11:40:31-06:00March 22nd, 2016|Categories: Company News, Industrial Hygiene Monitoring|Tags: , , , , , |0 Comments

SCADACore announces the release of their own Heat Stress Alarm Station. The SCADACore Sentinel Online Heat Stress Alarm Station provides users with the ability to set local alarms to trigger beacons and sirens alerting employees of potentially dangerous working conditions. The Alarm station is perfect of landscaping, mining operations, factories, ship yards, or any [...]

16 03, 2016

Emerson Roclink 800 Login Shortcut Key

2019-04-30T11:40:33-06:00March 16th, 2016|Categories: Oil And Gas Monitoring, Process Control|Tags: , , |0 Comments

For someone that uses roclink as much as me it can get tedious having to enter the default User ID (loi) and Password (1000) over and over again. There is a little known Roclink 800 Login Shortcut Key that can help save you a few seconds each time you try to login. At the RocLink 800 [...]

15 03, 2016

Converting Analog Input 4-20mA to 1-5V

2019-04-30T11:40:36-06:00March 15th, 2016|Categories: Devices, Environmental Monitoring, Health And Safety Monitoring, Industrial Hygiene Monitoring, Industrial Process Monitoring, Instrumentation, Oil And Gas Monitoring, Process Control, Remote Monitoring, Remote Surviellance, Renewable Energy|Tags: , , , , , , , |0 Comments

There are essentially 2 ways to read Analog inputs: reading current or reading voltage. Current is generally the most common because it can reach longer distances across the wire without losing analog input signal. Voltage, on the other-hand, will degrade over long distances producing inaccurate readings. When working with devices that only read 1-5V [...]

14 03, 2016

Sierra Wireless LS300 modem review

2019-04-30T11:40:37-06:00March 14th, 2016|Categories: Communications, Environmental Monitoring, Health And Safety Monitoring, Industrial Hygiene Monitoring, Industrial Process Monitoring, Oil And Gas Monitoring, Remote Monitoring, Remote Surviellance, Renewable Energy|Tags: , , , , , , |0 Comments

SCADACore uses several different forms of cellular communication for the SCADACore Live and Sentinel products. Unless you are very familiar with these products you probably do not know of their strengths and weaknesses. At SCADACore we deploy thousands of these modems so we have a good idea when to use and when to avoid [...]

7 07, 2015

Sierra Wireless Raven 1x CDMA Modem End of Life Migration

2019-04-30T11:40:41-06:00July 7th, 2015|Categories: Communications, Environmental Monitoring, Health And Safety Monitoring, Industrial Hygiene Monitoring, Industrial Process Monitoring, Oil And Gas Monitoring, Remote Monitoring, Remote Surviellance, Renewable Energy|Tags: , , , , , , , , , , , |0 Comments

CDMA Network End Of Life Cellular providers accross North America have standardized on the GSM network for a variety of reasons (http://www.pcmag.com/article2/0,2817,2407896,00.asp). As consumers we are left to find a solution to the end of life of the CDMA network. For the US this means that old hardware that used [...]

23 04, 2015

Roclink 800 Viewing Numeric Representation of TLPs

2019-04-30T11:40:42-06:00April 23rd, 2015|Categories: Communications, Devices, Oil And Gas Monitoring, Process Control, Remote Monitoring|Tags: , , , , |0 Comments

There are two separate representations of the Roclink “registers” called TLPs (Type/Logical/Parameter). They can be viewed as either Text such as AIN A1, EU – Analog Input, A1, EU value, or they can be viewed as the more commonly used numeric format 3,0,14. The Roclink Protocol Manual will use the [...]

9 01, 2015

Configuring Sierra Wireless Modems For Serial Pass Through

2019-06-18T17:57:07-06:00January 9th, 2015|Categories: Environmental Monitoring, Health And Safety Monitoring, Industrial Hygiene Monitoring, Industrial Process Monitoring, Oil And Gas Monitoring, Remote Monitoring, Remote Surviellance, Renewable Energy|Tags: , , , , , , , , , |0 Comments

When interfacing with remote devices via cellular modems the cell modem essentially acts as a serial bridge. From your computer over the internet to the Internet to the remote device. Sierra Wireless modems (http://www.sierrawireless.com/productsandservices/AirLink_Gateways_Modems/Intelligent_gateways.aspx) are some of the best in the industry but can be a little complex if you [...]